Publication Date
In 2025 | 0 |
Since 2024 | 0 |
Since 2021 (last 5 years) | 2 |
Since 2016 (last 10 years) | 6 |
Since 2006 (last 20 years) | 8 |
Descriptor
Correlation | 9 |
Exercise Physiology | 9 |
Metabolism | 5 |
Measurement | 4 |
Physical Activities | 4 |
Statistical Analysis | 4 |
Exercise | 3 |
Foreign Countries | 3 |
Measurement Techniques | 3 |
Physical Activity Level | 3 |
Physical Fitness | 3 |
More ▼ |
Source
Measurement in Physical… | 9 |
Author
Publication Type
Journal Articles | 9 |
Reports - Research | 7 |
Reports - Evaluative | 2 |
Education Level
Elementary Education | 1 |
Grade 1 | 1 |
Grade 2 | 1 |
Audience
Laws, Policies, & Programs
Assessments and Surveys
What Works Clearinghouse Rating
da Cruz, Carlos Janssen Gomes; Porto, Luiz Guilherme Grossi; Molina, Guilherme Eckhardt – Measurement in Physical Education and Exercise Science, 2022
The heart rate variability threshold (HRVT) is a useful and inexpensive alternative to estimate the ventilatory threshold (VT). However, its validity in women remains underexplored. We investigated the agreement between HRVT and VT in young women and the influence of cardiac parasympathetic status and cardiorespiratory fitness (CRF). Sixty-one…
Descriptors: Physical Fitness, Females, Young Adults, Measurement
Matthews, Evan L.; Horvat, Fiona M.; Phillips, David A. – Measurement in Physical Education and Exercise Science, 2022
The YMCA step test uses a prescribed step height which is difficult in a telehealth setting. Examine a modification of the YMCA step test allowing for the use of preexisting in-home objects of variable height as the "step" in a virtual environment. Young healthy participants (n = 40) performed step tests with a small and large object of…
Descriptors: Physical Fitness, Metabolism, Tests, Measurement
Chrismas, Bryna; Taylor, Lee; Smith, Alexander; Pemberton, Philip; Siegler, Jason Charles; Midgley, Adrian Wayne – Measurement in Physical Education and Exercise Science, 2018
To examine the reproducibility of three measurement techniques used to determine creatine kinase, interleukin-6 and high-sensitivity C-reactive protein, 50 participants had blood samples taken on two occasions. Fingertip plasma samples were analysed using the Reflotron for CK determination. Venous blood samples collected into serum separator tubes…
Descriptors: Measurement Techniques, Reliability, Biochemistry, Correlation
Bonafiglia, Jacob T.; Sawula, Laura J.; Gurd, Brendon J. – Measurement in Physical Education and Exercise Science, 2018
The purpose of this study was to determine if the counting talk test can be used to discern whether an individual is exercising above or at/below maximal lactate steady state. Twenty-two participants completed VO[subscript 2]peak and counting talk test incremental step tests followed by an endurance test at 65% of work rate at VO[subscript 2]peak…
Descriptors: Metabolism, Exercise, Tests, Physical Fitness
Driller, Matthew; Brophy-Williams, Ned; Walker, Anthony – Measurement in Physical Education and Exercise Science, 2017
The purpose of the present study was to determine the reliability of a 5km run test on a motorized treadmill. Over three consecutive weeks, 12 well-trained runners completed three 5km time trials on a treadmill following a standardized warm-up. Runners were partially-blinded to their running speed and distance covered. Total time to complete the…
Descriptors: Athletics, Physical Activities, Athletes, Test Reliability
McKie, Greg L.; Islam, Hashim; Townsend, Logan K.; Howe, Greg J.; Hazell, Tom J. – Measurement in Physical Education and Exercise Science, 2018
This study examined the validity and reliability of a 30-second running sprint test using two non-motorized treadmills compared to the established Wingate Anaerobic Test. Twenty-four participants completed three sessions in a randomized order on a: (1) manual mode treadmill (Woodway); (2) specialized interval training treadmill (HiTrainer); and…
Descriptors: Exercise, Physical Activities, Correlation, Exercise Physiology
Simpson, Rhianna Parker; Cronin, John – Measurement in Physical Education and Exercise Science, 2006
Drop jumping has previously been used to measure fast stretch shorten cycle (SSC) ability and stretch load tolerance. To the knowledge of these authors a test does not exist to achieve this in the horizontal direction. The purpose of this study therefore was to estimate the reliability of a new unilateral horizontal leg power test to assess these…
Descriptors: Correlation, Test Reliability, Exercise Physiology, Physical Activity Level
Scott, Alexander; Antonishen, Kevin; Johnston, Chris; Pearce, Terri; Ryan, Michael; Sheel, A. William; McKenzie, Don C. – Measurement in Physical Education and Exercise Science, 2006
The study was designed to determine the effect of upright-posture (UP) versus semirecumbent (SR) cycling on commonly used measures of maximal and submaximal exercise capacity. Nine healthy, untrained men (M age = 27 years, SD = 4.8 years) underwent steady-state submaximal aerobic testing followed by a ramped test to determine maximal oxygen…
Descriptors: Exercise, Testing, Exercise Physiology, Human Posture
Scruggs, Philip W.; Beveridge, Sandy K.; Clocksin, Brian D. – Measurement in Physical Education and Exercise Science, 2005
The relation and agreement of tri-axial accelerometry and heart rate telemetry in measuring moderate to vigorous physical activity were examined in association to behavioral observation during 1st- and 2nd-grade physical education. In Study 1, physical activity measures of heart rate and behavioral observation were collected on 346 participants…
Descriptors: Metabolism, Physical Education, Physical Activities, Observation