Publication Date
In 2025 | 0 |
Since 2024 | 0 |
Since 2021 (last 5 years) | 2 |
Since 2016 (last 10 years) | 6 |
Since 2006 (last 20 years) | 12 |
Descriptor
Source
Measurement in Physical… | 13 |
Author
Kang, Minsoo | 2 |
Ahn, Sun Joo | 1 |
Ainsworth, Barbara | 1 |
Bailey, Bruce W. | 1 |
Barry, Vaughn W. | 1 |
Bell, Mathew | 1 |
Boucher, Jean P. | 1 |
Boudreaux, Benjamin D. | 1 |
Brazendale, Keith | 1 |
Brian, Ali | 1 |
Callaway, Andrew J. | 1 |
More ▼ |
Publication Type
Journal Articles | 13 |
Reports - Research | 10 |
Reports - Evaluative | 3 |
Education Level
Elementary Education | 3 |
Grade 6 | 2 |
Junior High Schools | 2 |
Middle Schools | 2 |
Secondary Education | 2 |
Grade 5 | 1 |
Grade 7 | 1 |
Grade 8 | 1 |
Intermediate Grades | 1 |
Audience
Laws, Policies, & Programs
Assessments and Surveys
What Works Clearinghouse Rating
Schmidt, Michael D.; Rathbun, Stephen L.; Chu, Zhixuan; Boudreaux, Benjamin D.; Hahn, Lindsay; Novotny, Eric; Johnsen, Kyle; Ahn, Sun Joo – Measurement in Physical Education and Exercise Science, 2023
Physical activity (PA) estimates from the Fitbit Flex 2 were compared to those from the ActiGraph GT9X Link in 123 elementary school children. Steps and intensity-specific estimates of PA and 3-month PA change were calculated using two different ActiGraph cut-points (Evenson and Romanzini). Fitbit estimates were 35% higher for steps compared to…
Descriptors: Measurement Equipment, Physical Activity Level, Elementary School Students, After School Programs
Lind, Veronika; Svensson, Melanie; Harringe, Marita L. – Measurement in Physical Education and Exercise Science, 2022
Goniometry is commonly used to evaluate joint range of motion (ROM). The most widespread method, a manual universal goniometer (UG), is considered time-consuming and difficult to handle. The digital goniometer EasyAngle (EA) was developed to improve and simplify the evaluation of ROM. This study aimed to evaluate the reliability and validity of EA…
Descriptors: Motor Reactions, Measurement Techniques, Comparative Analysis, Measurement Equipment
Sacko, Ryan S.; Brazendale, Keith; Brian, Ali; McIver, Kerry; Nesbitt, Danielle; Pfeifer, Craig; Stodden, David F. – Measurement in Physical Education and Exercise Science, 2019
This study compared the energy expenditure (EE) levels during object projection skill performance (OPSP) as assessed by indirect calorimetry and accelerometry. Thirty-four adults (female n = 18) aged 18-30 (23.5 ± 2.5 years) performed three, 9-min sessions of kicking, over-arm throwing, and striking performed at 6-, 12-, and 30-sec intervals. EE…
Descriptors: Young Adults, Physical Activities, Measurement Techniques, Physical Activity Level
Bailey, Bruce W.; LeCheminant, Gabrielle; Hope, Timothy; Bell, Mathew; Tucker, Larry A. – Measurement in Physical Education and Exercise Science, 2018
The study compared the agreement, internal consistency, and measurement stability of the GE iDXA, BOD POD, and InBody 720. Body composition of 43 men and 37 women (31.4 ± 10.7 years; 90% Caucasian and 10% other) was assessed in triplicate using each method over two different days. Mean percent body fat (% BF) of the participants was different for…
Descriptors: Body Composition, Measurement Equipment, Reliability, Comparative Analysis
McKie, Greg L.; Islam, Hashim; Townsend, Logan K.; Howe, Greg J.; Hazell, Tom J. – Measurement in Physical Education and Exercise Science, 2018
This study examined the validity and reliability of a 30-second running sprint test using two non-motorized treadmills compared to the established Wingate Anaerobic Test. Twenty-four participants completed three sessions in a randomized order on a: (1) manual mode treadmill (Woodway); (2) specialized interval training treadmill (HiTrainer); and…
Descriptors: Exercise, Physical Activities, Correlation, Exercise Physiology
Kim, Youngdeok; Barry, Vaughn W.; Kang, Minsoo – Measurement in Physical Education and Exercise Science, 2015
This study examined (a) the validity of two accelerometers (ActiGraph GT3X [ActiGraph LLC, Pensacola, FL, USA] and activPAL [PAL Technologies Ltd., Glasgow, Scotland]) for the assessment of sedentary behavior; and (b) the variations in assessment accuracy by setting minimum sedentary bout durations against a proxy for direct observation using an…
Descriptors: Measurement Equipment, Life Style, Health Behavior, Accuracy
Gråstén, Arto; Watt, Anthony – Measurement in Physical Education and Exercise Science, 2016
The current article provides an important insight into measurement differences between two commonly used self-reports and accelerometer-determined moderate to vigorous physical activity (MVPA) scores within matched samples across 1 school year. Participants were 998 fifth- through eighth-grade students who completed self-reports and 76 fifth- and…
Descriptors: Comparative Analysis, Physical Activities, Physical Activity Level, Questionnaires
Callaway, Andrew J.; Cobb, Jon E. – Measurement in Physical Education and Exercise Science, 2012
Where as video cameras are a reliable and established technology for the measurement of kinematic parameters, accelerometers are increasingly being employed for this type of measurement due to their ease of use, performance, and comparatively low cost. However, the majority of accelerometer-based studies involve a single channel due to the…
Descriptors: Measurement Equipment, Motion, Athletics, Equipment Utilization
Liu, Wenhao; Nichols, Randall A.; Zillifro, Traci D. – Measurement in Physical Education and Exercise Science, 2013
This study compared a three-year tracking of health-related physical fitness between two comparable samples of six graders that enrolled either in a PE4life middle school ("n"?=?154) or another school with a traditional PE program ("n?"=?93) in the United States. For the cohort, the FITNESSGRAM[TM] (Cooper Institute for…
Descriptors: Physical Fitness, Physical Activity Level, Middle School Students, Grade 6
Zavorsky, Gerald S. – Measurement in Physical Education and Exercise Science, 2010
Measurement error is a common problem in several fields of research such as medicine, physiology, and exercise science. The standard deviation of repeated measurements on the same person is the measurement error. One way of presenting measurement error is called the repeatability, which is 2.77 multiplied by the within subject standard deviation.…
Descriptors: Physiology, Exercise Physiology, Medicine, Error of Measurement
Christie, A.; Kamen, G.; Boucher, Jean P.; Inglis, J. Greig; Gabriel, David A. – Measurement in Physical Education and Exercise Science, 2010
The Hoffmann reflex is obtained through surface electromyographic recordings, and it is one of the most common neurophysiological techniques in exercise science. Measurement and evaluation of the peak-to-peak amplitude of the Hoffmann reflex has been guided by the observation that it is a variable response that requires multiple trials to obtain a…
Descriptors: Motor Reactions, Measurement Techniques, Comparative Analysis, Statistical Analysis
Kang, Minsoo; Zhu, Weimo; Tudor-Locke, Catrine; Ainsworth, Barbara – Measurement in Physical Education and Exercise Science, 2005
Missing values are a common phenomenon in physical activity research, which has a negative impact on the quality of the data collected. The purpose of this study was to determine empirically the effectiveness of an individual information-centered (II-centered) approach in recovering step-count missing values by comparing the performance of the…
Descriptors: Physical Activity Level, Data, Measurement Techniques, Comparative Analysis
Hands, Beth; Parker, Helen; Larkin, Dawne – Measurement in Physical Education and Exercise Science, 2006
Many behavior patterns that impact on physical activity experiences are established in early childhood, therefore it is important that valid, reliable, and feasible measures are constructed to identify children who are not developing appropriate and healthy activity habits. In this study, measures of physical activity derived by accelerometry and…
Descriptors: Behavior Patterns, Play, Physical Activities, Observation