Publication Date
In 2025 | 1 |
Since 2024 | 3 |
Since 2021 (last 5 years) | 10 |
Since 2016 (last 10 years) | 18 |
Since 2006 (last 20 years) | 22 |
Descriptor
Foreign Countries | 22 |
Measurement Techniques | 22 |
Measurement Equipment | 11 |
Physical Activities | 8 |
Physical Activity Level | 8 |
Body Composition | 6 |
Validity | 6 |
Correlation | 5 |
Life Style | 5 |
Adults | 4 |
Comparative Analysis | 4 |
More ▼ |
Source
Measurement in Physical… | 22 |
Author
Ahmet Yildirim | 1 |
Baptista, Fatima | 1 |
Biddle, Stuart | 1 |
Blackburn, Nicole E. | 1 |
Bridge, Aaron D. | 1 |
Brown, Joseph | 1 |
Brønd, Jan Christian | 1 |
Caner Mavili | 1 |
Cantor Tarperi | 1 |
Caperchione, Cristina M. | 1 |
Caserotti, Paolo | 1 |
More ▼ |
Publication Type
Journal Articles | 22 |
Reports - Research | 20 |
Reports - Evaluative | 2 |
Education Level
Elementary Education | 4 |
Grade 5 | 3 |
Higher Education | 3 |
Postsecondary Education | 3 |
Secondary Education | 3 |
Grade 6 | 2 |
Intermediate Grades | 2 |
Middle Schools | 2 |
Grade 7 | 1 |
Grade 8 | 1 |
Junior High Schools | 1 |
More ▼ |
Audience
Location
Canada | 4 |
Australia | 3 |
United Kingdom | 3 |
Slovenia | 2 |
Asia | 1 |
Brazil | 1 |
Denmark | 1 |
Europe | 1 |
Finland | 1 |
Germany | 1 |
Ireland | 1 |
More ▼ |
Laws, Policies, & Programs
Assessments and Surveys
What Works Clearinghouse Rating
Samuel D'Emanuele; Francesca Nardello; Fabrizio Garau; Diego Campaci; Federico Schena; Cantor Tarperi – Measurement in Physical Education and Exercise Science, 2025
The agreement between a wearable inertial sensor (GYKO, G) and the force platform (P) was assessed by evaluating "test-retest" and "inter-rater reliability." Thirty-eight subjects were enrolled; the selected indices of balance were investigated over foot positions and (un)stable conditions. Intraclass correlation coefficient…
Descriptors: Human Posture, Measurement Equipment, Interrater Reliability, Measurement Techniques
Huseyin Celik; Ahmet Yildirim; Evrim Unver; Caner Mavili; Ekrem Yilmaz; Ferhat Ozturk; Pinar Arpinar-Avsar; Sukru Alpan Cinemre – Measurement in Physical Education and Exercise Science, 2024
The purpose was to evaluate reliability of measurements during drop jump (DJ) and magnitude of differences in vertical jump height (VJH) when calculated using two variables: time-in-the-air and center-of-mass velocity. Thirty-seven handball players performed three single-leg and double-leg DJs on a portable force plate during two sessions. Sixteen…
Descriptors: Measurement Techniques, Psychomotor Skills, Test Reliability, Computation
Isabella Toledo Caetano; Valter Paulo Neves Miranda; Fernanda Rocha de Faria; Cheryl Anne Howe; Paulo Roberto dos Santos Amorim – Measurement in Physical Education and Exercise Science, 2024
Latent Class Analysis (LCA) is a statistical method that can help researchers interested in better understanding the movement behaviors (MB) of children, based on the analysis of the level of physical activity (PA) and sedentary time (ST). This study aimed to evaluate and compare two models LCA (one for the accelerometer and one for the 24-hour…
Descriptors: Motion, Child Behavior, Multivariate Analysis, Measurement Techniques
Kozinc, Ziga; Smajla, Darjan; Trajkovic, Nebojsa; Sarabon, Nejc – Measurement in Physical Education and Exercise Science, 2022
This study aimed to assess intra- and inter-visit reliability of a novel EasyForce dynamometer for assessment of maximal strength in knee extension and flexion, and hip abduction and adduction tasks. Young healthy participants (n = 50; 25 males, 25 females; age: 23.4 ± 2.1 years) were measured for maximal joint torque with EasyForce dynamometer…
Descriptors: Measurement Equipment, Muscular Strength, Human Body, Young Adults
Coyle-Asbil, Hannah J.; Ma, David W. L.; Vallis, Lori Ann – Measurement in Physical Education and Exercise Science, 2022
This study explored (1) the effect of applying an autocalibration algorithm on accelerometer data analyzed using different signal processing techniques and (2) how these techniques changed the signal composition. Using a dataset of preschoolers (n = 137; 4.31 ± 0.87 years; Actigraph accelerometers (100 Hz) on right hip 24 hours/7 days) the vector…
Descriptors: Preschool Children, Motion, Physical Activities, Sleep
Lind, Veronika; Svensson, Melanie; Harringe, Marita L. – Measurement in Physical Education and Exercise Science, 2022
Goniometry is commonly used to evaluate joint range of motion (ROM). The most widespread method, a manual universal goniometer (UG), is considered time-consuming and difficult to handle. The digital goniometer EasyAngle (EA) was developed to improve and simplify the evaluation of ROM. This study aimed to evaluate the reliability and validity of EA…
Descriptors: Motor Reactions, Measurement Techniques, Comparative Analysis, Measurement Equipment
Edwardson, Charlotte L.; Maylor, Benjamin D.; Dawkins, Nathan P.; Plekhanova, Tatiana; Rowlands, Alex V. – Measurement in Physical Education and Exercise Science, 2022
The aim was to establish which postural and physical activity outcomes are comparable across different accelerometer brands worn on the thigh when processed using open-source methods. Twenty participants wore four accelerometers (Axivity, ActiGraph, activPAL, GENEActiv) for three free-living days. Postural and physical activity outputs (average…
Descriptors: Human Posture, Physical Activity Level, Measurement Equipment, Life Style
Krkeljas, Zarko; Engelbrecht, Louise; Terblanche, Elmarie – Measurement in Physical Education and Exercise Science, 2019
Accurate assessment of resting metabolic rate (RMR) is necessary for calorie-based recommendations in diet and exercise training interventions. BodyMetrix™ is an ultrasound-based device that provides an estimate of RMR based on body composition, but has not been proven valid or reliable. Therefore, we evaluated the agreement between Katch-McArdle…
Descriptors: Foreign Countries, Adults, Measurement Techniques, Metabolism
Bridge, Aaron D.; Brown, Joseph; Snider, Hayden; Rowan, Shannon N.; Skelly, Lauren E.; Josse, Andrea R. – Measurement in Physical Education and Exercise Science, 2021
Body composition (BC) is a valuable indicator of health and performance. Air-displacement plethysmography (ADP) is a popular, efficient, and reliable method for assessing BC. A-mode ultrasonography (AUS) is another method, and its affordability, mobility, and practicality make it a plausible device for industry and health professionals. This study…
Descriptors: Body Composition, Body Weight, Body Height, Exercise Physiology
Kastelic, Kaja; Šarabon, Nejc – Measurement in Physical Education and Exercise Science, 2019
Self-reports are commonly used tools for obtaining sedentary behaviors. The aim of our study was to assess agreement between two self-reports of sedentary time and a gold standard sedentary time objective monitor. A worksite sample (n = 42) completed the Slovenian version of the Global Physical Activity Questionnaire (GPAQ), the Slovenian version…
Descriptors: Physical Activity Level, Measurement Techniques, Measurement Equipment, Foreign Countries
Janz, Kathleen F.; Baptista, Fatima; Ren, Sicong; Zhu, Weimo; Laurson, Kelly R.; Mahar, Matthew T.; Pavlovic, Andjelka; Welk, Gregory J. – Measurement in Physical Education and Exercise Science, 2022
This study summarized protocols in the "Lisbon Study for the Development and Evaluation of Musculoskeletal Fitness Standards in Youth" and assessed associations between fitness assessments and health outcomes. The sample was 529 children and adolescents (10 to 18 yr). The fitness assessments included handgrip, vertical jump, long jump,…
Descriptors: Physical Fitness, Tests, Muscular Strength, Psychomotor Skills
Sansano-Nadal, Oriol; Wilson, Jason J.; Martín-Borràs, Carme; Brønd, Jan Christian; Skjødt, Mathias; Caserotti, Paolo; Roqué I. Figuls, Marta; Blackburn, Nicole E.; Klenk, Jochen; Rothenbacher, Dietrich; Guerra-Balic, Myriam; Font-Farré, Manel; Denkinger, Michael; Coll-Planas, Laura; Deidda, Manuela; McIntosh, Emma; Giné-Garriga, Maria; Tully, Mark A. – Measurement in Physical Education and Exercise Science, 2022
The main aim of this study was to assess the criterion validity of the Sedentary Behavior Questionnaire (SBQ) to measure SB in community-dwelling older adults using thigh-measured accelerometry as the criterion method. 801 participants (75.6 ± 6.1 years old, 57.6% females) provided valid thigh-based accelerometer data (activPAL/Axivity) and…
Descriptors: Physical Activity Level, Life Style, Older Adults, Foreign Countries
Myers, Nicholas D.; Lee, Seungmin; Kostelis, Kimberly T. – Measurement in Physical Education and Exercise Science, 2018
The purpose of this annual report is to provide a summary of measurement in physical education and exercise science-related activities in 2017. A recent trend for an annual increase in manuscript submissions to measurement in physical education and exercise science continued in 2017. Twenty-nine countries were represented (i.e., corresponding…
Descriptors: Physical Education, Exercise, Measurement Techniques, Foreign Countries
McKie, Greg L.; Islam, Hashim; Townsend, Logan K.; Howe, Greg J.; Hazell, Tom J. – Measurement in Physical Education and Exercise Science, 2018
This study examined the validity and reliability of a 30-second running sprint test using two non-motorized treadmills compared to the established Wingate Anaerobic Test. Twenty-four participants completed three sessions in a randomized order on a: (1) manual mode treadmill (Woodway); (2) specialized interval training treadmill (HiTrainer); and…
Descriptors: Exercise, Physical Activities, Correlation, Exercise Physiology
Murphy, Joseph J.; Murphy, Marie H.; MacDonncha, Ciaran; Murphy, Niamh; Nevill, Alan M.; Woods, Catherine B. – Measurement in Physical Education and Exercise Science, 2017
The purpose of this study was to compare the validity and reliability of three short physical activity self-report instruments to determine their potential for use with university student populations. The participants (N = 155; 44.5% male; 22.9 ± 5.13 years) wore an accelerometer for 9 consecutive days and completed a single-item measure, the a…
Descriptors: Physical Activities, Physical Activity Level, Validity, Reliability
Previous Page | Next Page »
Pages: 1 | 2