Publication Date
In 2025 | 1 |
Since 2024 | 4 |
Since 2021 (last 5 years) | 12 |
Since 2016 (last 10 years) | 20 |
Since 2006 (last 20 years) | 28 |
Descriptor
Measurement Techniques | 29 |
Reliability | 15 |
Test Reliability | 12 |
Foreign Countries | 9 |
Measurement Equipment | 8 |
Physical Activities | 8 |
Validity | 8 |
Adults | 7 |
Human Body | 7 |
Statistical Analysis | 7 |
Test Validity | 7 |
More ▼ |
Source
Measurement in Physical… | 29 |
Author
Abdullah Uysal | 1 |
Ahmet Yildirim | 1 |
Angulo-Barroso, Rosa M. | 1 |
Bailey, Bruce W. | 1 |
Balasubramani, Saravanan | 1 |
Bateman, André G. | 1 |
Bell, Mathew | 1 |
Bliss, Alex | 1 |
Boucher, Jean P. | 1 |
Brian, Ali | 1 |
Brincks, Ahnalee M. | 1 |
More ▼ |
Publication Type
Journal Articles | 29 |
Reports - Research | 25 |
Reports - Evaluative | 3 |
Information Analyses | 2 |
Tests/Questionnaires | 1 |
Education Level
Higher Education | 3 |
Postsecondary Education | 2 |
Audience
Location
Slovenia | 2 |
Australia | 1 |
Canada | 1 |
Florida | 1 |
Ireland | 1 |
Italy | 1 |
New York | 1 |
North Carolina | 1 |
Sweden | 1 |
Turkey (Ankara) | 1 |
United Kingdom | 1 |
More ▼ |
Laws, Policies, & Programs
Assessments and Surveys
What Works Clearinghouse Rating
Samuel D'Emanuele; Francesca Nardello; Fabrizio Garau; Diego Campaci; Federico Schena; Cantor Tarperi – Measurement in Physical Education and Exercise Science, 2025
The agreement between a wearable inertial sensor (GYKO, G) and the force platform (P) was assessed by evaluating "test-retest" and "inter-rater reliability." Thirty-eight subjects were enrolled; the selected indices of balance were investigated over foot positions and (un)stable conditions. Intraclass correlation coefficient…
Descriptors: Human Posture, Measurement Equipment, Interrater Reliability, Measurement Techniques
Haiko Bruno Zimmermann; Debora Knihs; Raphael Sakugawa; Chris Bishop; Juliano Dal Pupo – Measurement in Physical Education and Exercise Science, 2024
Background: Measures that assess muscle strength and its development, either voluntarily or involuntarily, are important in the clinical and research context. The main aim of this study was to verify the interday reliability and the minimum detectable change (MDC) of the knee extensors muscles torque using evoked contractions and explosive…
Descriptors: Human Body, Physiology, Motor Reactions, Muscular Strength
Huseyin Celik; Ahmet Yildirim; Evrim Unver; Caner Mavili; Ekrem Yilmaz; Ferhat Ozturk; Pinar Arpinar-Avsar; Sukru Alpan Cinemre – Measurement in Physical Education and Exercise Science, 2024
The purpose was to evaluate reliability of measurements during drop jump (DJ) and magnitude of differences in vertical jump height (VJH) when calculated using two variables: time-in-the-air and center-of-mass velocity. Thirty-seven handball players performed three single-leg and double-leg DJs on a portable force plate during two sessions. Sixteen…
Descriptors: Measurement Techniques, Psychomotor Skills, Test Reliability, Computation
Ripley, Nicholas; Comfort, Paul; McMahon, John – Measurement in Physical Education and Exercise Science, 2023
The aim of the present study was to determine the reliability and differences between three fascicle length (FL) estimation methods when utilizing a 10-cm ultrasound (US) probe. Thirteen males (24.1 ± 3.8 years, 79.3 ± 14 kg, 179 ± 6.6 cm) participated. Bicep femoris long head (BFLH) US images were collected on two separate occasions. Three…
Descriptors: Measurement Techniques, Computation, Human Body, Measurement Equipment
Pérez-Castilla, Alejandro; García-Ramos, Amador – Measurement in Physical Education and Exercise Science, 2021
An a-posteriori multicentre reliability study was conducted to compare the reliability and magnitude of the maximum power (P[subscript max]) and optimal velocity (V[subscript opt]) between the force-power-velocity relationships during the leg cycle-ergometer and bench press throw exercises. The force-power-velocity relationships were determined in…
Descriptors: Motion, Exercise, Measurement Techniques, Reliability
Yücel Makaraci; Kazim Nas; Kerem Gündüz; Abdullah Uysal; Samuel T. Orange; Juan D. Ruiz-Cárdenas – Measurement in Physical Education and Exercise Science, 2024
The aim was to determine the validity and test-retest reliability of the Sit to Stand App variables (rising time, vertical velocity, and power) for measuring single-leg sit-to-stand (STS) test compared to those derived from ground reaction force data. Twenty-seven female athletes performed the single-leg STS test over three consecutive sessions…
Descriptors: Computer Simulation, Measurement Techniques, Athletics, Physical Fitness
Takeno, Katsumi; Norte, Grant E.; Glaviano, Neal R.; Khuder, Sadik; Ingersoll, Christopher D. – Measurement in Physical Education and Exercise Science, 2023
Reliable techniques to assess centrally mediated function in healthy individuals are essential to understand the origins of neuromuscular dysfunction in pathologic populations. This study examined the test-retest reliability of corticospinal excitability in the upper extremity musculature of 21 healthy individuals using transcranial magnetic…
Descriptors: Measurement Techniques, Human Body, Reliability, Neurological Organization
Kozinc, Ziga; Smajla, Darjan; Trajkovic, Nebojsa; Sarabon, Nejc – Measurement in Physical Education and Exercise Science, 2022
This study aimed to assess intra- and inter-visit reliability of a novel EasyForce dynamometer for assessment of maximal strength in knee extension and flexion, and hip abduction and adduction tasks. Young healthy participants (n = 50; 25 males, 25 females; age: 23.4 ± 2.1 years) were measured for maximal joint torque with EasyForce dynamometer…
Descriptors: Measurement Equipment, Muscular Strength, Human Body, Young Adults
Ren, Sicong; Chen, Zezhao; Qin, Xiong; Zhao, Xiaochen; Yang, Tim D.; Zhu, Weimo – Measurement in Physical Education and Exercise Science, 2021
The purpose of this study was to overview recent bone loading measurements in physical activity, determine their validity and reliability, and recommend future research directions. A systematic search in three major databases was performed using combinations from a set of keywords, and the identified studies were selected using predetermined…
Descriptors: Measurement Techniques, Validity, Reliability, Physical Activities
Lind, Veronika; Svensson, Melanie; Harringe, Marita L. – Measurement in Physical Education and Exercise Science, 2022
Goniometry is commonly used to evaluate joint range of motion (ROM). The most widespread method, a manual universal goniometer (UG), is considered time-consuming and difficult to handle. The digital goniometer EasyAngle (EA) was developed to improve and simplify the evaluation of ROM. This study aimed to evaluate the reliability and validity of EA…
Descriptors: Motor Reactions, Measurement Techniques, Comparative Analysis, Measurement Equipment
Bliss, Alex; Dekerle, Jeanne – Measurement in Physical Education and Exercise Science, 2019
Knee flexor and extensor muscular assessment via isokinetic dynamometry is common practice and established in the research literature. However, reporting assessment methodology regarding reciprocal and nonreciprocal movements is often vague or absent. Such methodological issues are crucial for accurate assessments. Therefore, knee extensor and…
Descriptors: Motor Reactions, Muscular Strength, Males, Test Reliability
Myers, Nicholas D.; Lee, Seungmin; Bateman, André G.; Wekesser, Meredith; Prilleltensky, Isaac; McMahon, Adam; Brincks, Ahnalee M. – Measurement in Physical Education and Exercise Science, 2023
The objective of this study was to provide initial validity evidence for responses to the newly developed Well-Being Actions Self-Efficacy (WBASE) scale from adults with obesity under an exploratory latent variable approach. Longitudinal data (N[subscript baseline] = 667 and N[subscript 30 days post-baseline] = 550) from the Well-Being and…
Descriptors: Test Validity, Self Efficacy, Adults, Obesity
Kastelic, Kaja; Šarabon, Nejc – Measurement in Physical Education and Exercise Science, 2019
Self-reports are commonly used tools for obtaining sedentary behaviors. The aim of our study was to assess agreement between two self-reports of sedentary time and a gold standard sedentary time objective monitor. A worksite sample (n = 42) completed the Slovenian version of the Global Physical Activity Questionnaire (GPAQ), the Slovenian version…
Descriptors: Physical Activity Level, Measurement Techniques, Measurement Equipment, Foreign Countries
Chrismas, Bryna; Taylor, Lee; Smith, Alexander; Pemberton, Philip; Siegler, Jason Charles; Midgley, Adrian Wayne – Measurement in Physical Education and Exercise Science, 2018
To examine the reproducibility of three measurement techniques used to determine creatine kinase, interleukin-6 and high-sensitivity C-reactive protein, 50 participants had blood samples taken on two occasions. Fingertip plasma samples were analysed using the Reflotron for CK determination. Venous blood samples collected into serum separator tubes…
Descriptors: Measurement Techniques, Reliability, Biochemistry, Correlation
Pennell, Adam; Patey, Matthew; Fisher, Jenna; Brian, Ali – Measurement in Physical Education and Exercise Science, 2022
Falls are a significant medical and economical concern worldwide. Younger individuals with visual impairment (VI) may be more susceptible to falling and fall-related injuries when compared to peers without a VI. Self-perceived balance confidence is a psychological construct that may predict and/or mediate fall- or other health-related outcomes in…
Descriptors: Psychomotor Skills, Self Efficacy, Accidents, Injuries
Previous Page | Next Page »
Pages: 1 | 2